ISO 14644-1
The current international standard. It sets the class by the number of particles allowed in one cubic metre of air, from ISO 1 (cleanest) to ISO 9. Most new rooms are specified this way.
Federal Standard 209E
The older US standard. Classes were named by particles of 0.5 micron and larger per cubic foot, so Class 100 means about 100 per cubic foot. It was withdrawn in 2001 and replaced by ISO 14644-1, but the names are still common in drawings, specifications and conversation.
EU GMP Annex 1
Used for sterile pharmaceutical manufacture. It uses grades A to D, set for two states: at rest and in operation. It also sets limits for micro-organisms, which the other two do not.
How they line up
| ISO 14644-1 | Fed Std 209E | EU GMP | Typical use |
|---|---|---|---|
| ISO 5 | Class 100 | Grade A (and B at rest) | Aseptic filling, critical wafer steps |
| ISO 6 | Class 1,000 | No direct grade | Clean assembly, medical devices |
| ISO 7 | Class 10,000 | Grade B in operation, C at rest | Pharma support areas, electronics assembly |
| ISO 8 | Class 100,000 | Grade C in operation, D at rest | Gowning areas, general controlled spaces |
What to remember
- Lower numbers are cleaner in ISO. In Fed Std, a lower class number is also cleaner.
- The match is approximate. The methods and test conditions differ, so treat the table as a guide.
- Grades are not just particles. GMP also looks at microbes, gowning and process controls.
- Supplies follow the class. Tighter rooms need low-shedding wipers, sealed-border garments and cleanroom gloves.