Cleanroom classes compared: ISO 14644, Fed Std 209E and EU GMP

You will see cleanrooms described as ISO 5, Class 100 or Grade A. They are three naming systems for related levels of cleanliness. This guide puts them side by side.

Cleanroom classes compared: ISO 14644-1, Federal Standard 209E and EU GMP grades, with particle limits THREE WAYS TO NAME THE SAME CLEANLINESS ISO 14644-1Current standard Fed Std 209EWithdrawn 2001 EU GMP Annex 1Pharma grades 0.5 micronMax per m3 ISO 3 Class 1 — 35 ISO 4 Class 10 — 352 ISO 5 Class 100 Grade A (and B at rest) 3,520 ISO 6 Class 1,000 — 35,200 ISO 7 Class 10,000 Grade B in operation, C at rest 352,000 ISO 8 Class 100,000 Grade C in operation, D at rest 3,520,000 ISO 9 No equivalent — 35,200,000 Cleaner at the top. Fed Std counts are per cubic foot, shown here as per cubic metre.
Rough equivalence only. GMP grades also set microbial limits. Your quality team maps grades and classes for your site.

ISO 14644-1

The current international standard. It sets the class by the number of particles allowed in one cubic metre of air, from ISO 1 (cleanest) to ISO 9. Most new rooms are specified this way.

Federal Standard 209E

The older US standard. Classes were named by particles of 0.5 micron and larger per cubic foot, so Class 100 means about 100 per cubic foot. It was withdrawn in 2001 and replaced by ISO 14644-1, but the names are still common in drawings, specifications and conversation.

EU GMP Annex 1

Used for sterile pharmaceutical manufacture. It uses grades A to D, set for two states: at rest and in operation. It also sets limits for micro-organisms, which the other two do not.

How they line up

ISO 14644-1Fed Std 209EEU GMPTypical use
ISO 5Class 100Grade A (and B at rest)Aseptic filling, critical wafer steps
ISO 6Class 1,000No direct gradeClean assembly, medical devices
ISO 7Class 10,000Grade B in operation, C at restPharma support areas, electronics assembly
ISO 8Class 100,000Grade C in operation, D at restGowning areas, general controlled spaces

What to remember

  • Lower numbers are cleaner in ISO. In Fed Std, a lower class number is also cleaner.
  • The match is approximate. The methods and test conditions differ, so treat the table as a guide.
  • Grades are not just particles. GMP also looks at microbes, gowning and process controls.
  • Supplies follow the class. Tighter rooms need low-shedding wipers, sealed-border garments and cleanroom gloves.
Limits, test methods and grades come from the standards and your regulator. Check the current edition and confirm with your quality team. This is not a compliance statement.